Quick Response Time Long Term
Calibration Stability Low Power Consumption
Detcon toxic
gas electrochemical gas sensor assemblies are designed to monitor ambient air
for the presence of a wide variety of toxic gas compounds. The Detcon list of
measurable toxic gases and the availability of full-scale ranges are among the
most extensive in the gas detection industry. The detection technology is the
3-electrode electrochemical cell type. Each cell consists of three electrodes
embedded in an electrolyte and is housed beneath a gas diffusion membrane.
Sensitivity and specificity to each target gas is achieved by varying the
composition of the electrodes and/or the electrolyte solution.
The
electrochemical cell is the most widely applied sensor design for detection of
toxic gases. While there are certain specific applications where other sensor
designs can be used to good effect (e.g. the metal oxide semiconductor and the
photo-ionization detector), the electrochemical cell remains the most widely
accepted for use in monitoring a broad range of gases. Detcon has a long
history in the adaptation and application of electrochemical sensors, and the
resultant product line makes optimal use of the many advantages of the
technology.
DM-400IS Detcon Model DM-400IS toxic gas detectors
are a traditional explosion-proof sensor assembly with blind cover.
Operator interface is via test points and span potentiometers accessed through
the transmitter faceplate.
Standard 4-20 mA
DM-500IS Detcon Model DM-500IS toxic gas detectors
are non-intrusive intelligent sensors featuring Detcon Microsafe
intuitive software. Operator interface is via a hand-held magnet and program
switches accessed through a glass lens cover.
Microsafe
Sensor 4-20 mA Output Non-Intrusive Interface
DM-600IS Model series 600 sensors provide complete
flexibility in system integration options. Standard outputs include a linear
4-20 milliamp signal, three alarm relays and an RS-485 serial communication
port.
DM-700 Detcon Model FP-700 toxic gas
detection sensors are an improved non-intrusive intelligent sensor with a wide
variety of communication options and added features.
Air and target gas diffuse through the diffusion barrier to reach
the sensing electrode. The controlling circuit maintains an external operating
voltage between the sensing and counter electrodes sufficient to drive the
electrochemical reaction. The electrochemical reaction with the target gas
generates a current flow between the sensing and counter electrodes. This
current is proportional to the target gas concentration and is reversible. The
electronic circuit also provides a specific bias potential between the
reference and the sensor electrodes in such a manner that no current flows
between them. The quick response of the sensor results in continuous monitoring
of ambient air conditions.
Detectable Gases
Acetaldehyde
C2H3O
Ethanol
C2H5OH
Hydrogen Sulfide
H2S
Acetylene
C2H2
Ethyl
Mercaptan
C2H5SH
Methanol
CH3OH
Acrylonitrile
C3H3N
Ethylene
C2H4
Methyl
Mercaptan
CH3SH
Ammonia
NH3
Ethylene Oxide
C2H4O
Nitric Oxide
NO
Arsine
AsH3
Fluorine
F2
Nitrogen Dioxide
NO2
Bromine
Br2
Formaldehyde
CH2O
Ozone
O3
Butadiene
C4H6
Germane
GeH4
Phosgene
COCl2
Carbon Monoxide
CO
Hydrazine
N2H4
Phosphine
PH3
Carbonyl
Sulfide
COS
Hydrogen PPM
H2
Silane
SiH4
Chlorine
Cl2
Hydrogen LEL
H2
Sulfur Dioxide
SO2
Chlorine Dioxide
ClO2
Hydrogen 0-1%
H2
Tetrahydrothiophene
C4H8S
Diborane
B2H6
Hydrogen
Bromide
HBr
Thiophane
C4H4S
Dimethyl Sulfide
C2H6S
Hydrogen Chloride
HCl
Vinyl Acetate
C4H6O2
Epichlorohydrin
C3H5OCl
Hydrogen Cyanide
HCN
Vinyl Chloride
C2H3Cl
Hydrogen Fluoride
HF
Call for others. . .
Detcon Inc. 3200 Research Forest Drive, A-1
The Woodlands, Texas 77381, USA Phone 713-559-9200 Toll Free
888-367-4286 Fax 281-292-2860 Email:
sales@detcon.com