Detcon toxic gas electrochemical gas sensor assemblies are designed to monitor ambient air for the presence of a wide variety of toxic gas compounds. The Detcon list of measurable toxic gases and the availability of full-scale ranges are among the most extensive in the gas detection industry. The detection technology is the 3-electrode electrochemical cell type. Each cell consists of three electrodes embedded in an electrolyte and is housed beneath a gas diffusion membrane. Sensitivity and specificity to each target gas is achieved by varying the composition of the electrodes and/or the electrolyte solution.

The electrochemical cell is the most widely applied sensor design for detection of toxic gases. While there are certain specific applications where other sensor designs can be used to good effect (e.g. the metal oxide semiconductor and the photo-ionization detector), the electrochemical cell remains the most widely accepted for use in monitoring a broad range of gases. Detcon has a long history in the adaptation and application of electrochemical sensors, and the resultant product line makes optimal use of the many advantages of the technology.

In addition, an Intrinsically Safe UniTox™ DM-200 version is covered separately.


Certifications
DM-200 Unitox CSA
DM-400IS CSA
DM-500IS CSA
DM-600IS CSA
DM-700 CSA
UL Sensors Classified Can.pdf
UL Sensors Classified US.pdf
ATEX 700-DM-Toxics


DM-400IS
Detcon Model DM-400IS toxic gas detectors are a traditional explosion-proof sensor assembly with “blind” cover. Operator interface is via test points and span potentiometers accessed through the transmitter faceplate.

• Standard 4-20 mA



DM-500IS
Detcon Model DM-500IS toxic gas detectors are non-intrusive intelligent sensors featuring Detcon Microsafe™ intuitive software. Operator interface is via a hand-held magnet and program switches accessed through a glass lens cover.

• Microsafe Sensor
• 4-20 mA Output
• Non-Intrusive Interface

DM-600IS
Model series 600 sensors provide complete flexibility in system integration options. Standard outputs include a linear 4-20 milliamp signal, three alarm relays and an RS-485 serial communication port.

• Microsafe Sensor
• 4-20 mA, RS-485, Relays
• Non-Intrusive Interface

DM-700
Detcon Model FP-700 toxic gas detection sensors are an improved non-intrusive intelligent sensor with a wide variety of communication options and added features.

• Microsafe Sensor
• 4-20 mA, RS-485, Relays
• Non-Intrusive Interface
• Environmentally Bulletproof
• Electropolished 316SS
• 100% Encapsulated Circutry
• Water-Corrosion Proof
• Multi-Layer Surge Protection
• Preemptive Fault Diagonostics
SIL 2 Compliant

Principle of Operation

Air and target gas diffuse through the diffusion barrier to reach the sensing electrode. The controlling circuit maintains an external operating voltage between the sensing and counter electrodes sufficient to drive the electrochemical reaction. The electrochemical reaction with the target gas generates a current flow between the sensing and counter electrodes. This current is proportional to the target gas concentration and is reversible. The electronic circuit also provides a specific bias potential between the reference and the sensor electrodes in such a manner that no current flows between them. The quick response of the sensor results in continuous monitoring of ambient air conditions.

Detectable Gases

Acetaldehyde   C2H3O   Ethanol   C2H5OH   Hydrogen Sulfide   H2S
Acetylene   C2H2   Ethyl Mercaptan   C2H5SH   Methanol   CH3OH
Acrylonitrile   C3H3N   Ethylene   C2H4   Methyl Mercaptan   CH3SH
Ammonia   NH3   Ethylene Oxide   C2H4O   Nitric Oxide   NO
Arsine   AsH3   Fluorine   F2   Nitrogen Dioxide   NO2
Bromine   Br2   Formaldehyde   CH2O   Ozone   O3
Butadiene   C4H6   Germane   GeH4   Phosgene   COCl2
Carbon Monoxide   CO   Hydrazine   N2H4   Phosphine   PH3
Carbonyl Sulfide   COS   Hydrogen PPM   H2   Silane   SiH4
Chlorine   Cl2   Hydrogen LEL   H2   Sulfur Dioxide   SO2
Chlorine Dioxide   ClO2   Hydrogen 0-1%   H2   Tetrahydrothiophene   C4H8S
Diborane   B2H6   Hydrogen Bromide   HBr   Thiophane   C4H4S
Dimethyl Sulfide   C2H6S   Hydrogen Chloride   HCl   Vinyl Acetate   C4H6O2
Epichlorohydrin   C3H5OCl   Hydrogen Cyanide   HCN   Vinyl Chloride   C2H3Cl
    Hydrogen Fluoride   HF   Call for others. . .    

PDF Documentation - Electrochemical Gas Detection Sensors
Toxic 6-page Full Color Brochure - 533K
Model Series 700 - 6-panel full color brochure - 447K
DM-400IS Data Sheets By Gas Type DM-400IS Engineering Specifications
DM-500IS Data Sheets By Gas Type   DM-500IS Engineering Specifications
 
DM-600IS Data Sheets By Gas Type   DM-600IS Engineering Specifications
 
 DM-700 Data Sheets By Gas Type    DM-700 Engineering Specifications
 