Model
1000 Process Gas Analyzers
| |
Continuous measurement with superior
uptime |
| |
Simple to operate |
| |
Calibration maintenance only |
| |
Low cost of ownership |
| |
No hazardous waste disposal |
| |
Sample gas upset protection standard |
| |
Standard outputs: 4-20mA, RS-485, and 3
relays |
| |
Class I, Div. 1, Groups C, D rated |
The Detcon Model 1000 family
of process analyzers has been designed to provide accurate and continuous
measurement of target gas concentrations in all types of process gas streams.
Model 1000 analyzers offer the end-user a space-efficient modular design,
simple field calibration, and minimal maintenance over a wide variety of target
gas applications. The applications flexibility of this analyzer family comes
from utilization of a variety of proven sensor technologies. This in turn
allows customization according to the needs of the process.
|
|
Detcon Model series
1000-H2S
process analyzers provide continuous, real-time measurement
of H2S concentrations in natural gas pipelines, tail gas lines,
SRU overhead gas lines, as well as other applications. Available
ranges are from 0-10 ppm up to 0-1%. Other ranges are available
on request. The system can be provided with on-board manual
calibration. The design employs Detcons proprietary solid
state MOS sensor element with a ten-year conditional warranty.
The analyzer features a microprocessor-based signal-conditioning
transmitter with local digital display, fault supervision, calibration
mode indicator, alarm relays and an RS-485 serial port. The
instrument package is rated for use in electrically classified
areas: Class I; Division 1; Groups C, and D. Line power, battery
and solar powered models are available. |
|
Detcon Model
1000-CO2 process analyzers provide continuous, real-time
measurement of CO2 concentrations in natural gas pipelines, gas treating
plants, SRU overhead gas lines, as well as other applications. Available ranges
are from 0-3,000 ppm up to 0-100%. The system can be provided with optional
on-board manual calibration. This design employs Detcons sub-miniature
NDIR optical sensor element with a five-year conditional warranty. The analyzer
features a microprocessor-based signal conditioning transmitter with local
digital display, fault supervision, calibration mode indicator, alarm relays
and an RS-485 serial port. The instrument package is rated for use in
electrically classified areas: Class I; Division 1; Groups C, and D. Line
power, battery and solar powered models are available. 0-5% CO2 Range Shown
with Sample Flow Fault Option |
|
Detcon Model
1000-H2S/CO2 dual process analyzers provide simultaneous and
continuous measurement of both H2S and CO2 concentrations. Available ranges for
H2S are from 0-10 ppm up to 0-1% volume. Available ranges for CO2 are from
0-0.3% up to 0-100%. CO2 detection is made using Detcons sub-miniature
NDIR optical sensor element with a five-year conditional warranty. H2S
detection is made using Detcons proprietary solid-state MOS H2S sensor
element with a 10-year conditional warranty. The analyzer features
microprocessor-based signal-conditioning transmitters with local digital
display, fault supervision, calibration mode indicator, alarm relays and an
RS-485 serial port. The instrument package is rated for use in electrically
classified areas: Class I; Division 1; Groups C, and D. Line power, battery and
solar powered models are available. |
|
Portable H2S Analyzer Detcon
Model P-1000-H2S The Detcon Model P-1000-H2S is a portable gas
analyzer designed to provide accurate measurement of Hydrogen Sulfide gas
concentrations in natural gas wells, natural gas pipelines and in the outlet
from natural gas treating plants. The portable battery powered instrument
utilizes advanced electrochemical sensor technology and microprocessor based
electronic control circuitry that includes a built-in portable data logger.
Stored data can be downloaded to a spreadsheet and used to create trend graphs,
average readings and peak values. A universal signal conditioning circuit with
an LCD display and any one of three intelligent sensor modules can be combined
to provide ranges of measurement of 0-20 PPM, 0-100 PPM or 0-1000PPM. The
analyzer sensor and control circuitry are mounted in a weatherproof enclosure
with a built-in battery supply and secondary sample conditioning components.
The Model P-1000-H2S is capable of continuous operation for a period of
approximately 30 days before battery recharge is required. The intrinsically
safe design is suitable for hazardous area usage. Electrical Class: Class
I; Div1; EEx ia IIC T3C Enclosure Class: NEMA 4X, IP 66 |
|
|